Force putting save_data on the stack rather than in SSE register
The signal management does not yet properly save SSE state, so that save_data
would get overwritten by signal handlers, notably leading to `` shell
replacement getting empty content because then the io_read RPC retry gets an
MIG_BAD_ARGUMENTS error.
XXX: This is only temporary to fix the common shll replacement issue, and is
waiting for proper SSE state restoration.
Gbp-Pq: Topic hurd-i386
Gbp-Pq: Name local-intr-msg-clobber.diff
mach_msg_bits_t msgh_bits;
mach_port_t remote_port;
mach_msg_id_t msgid;
- struct clobber save_data;
+ volatile struct clobber save_data;
if ((option & (MACH_SEND_MSG|MACH_RCV_MSG)) != (MACH_SEND_MSG|MACH_RCV_MSG)
|| _hurd_msgport_thread == MACH_PORT_NULL)