hpet_setup() is idempotent if the rate has already been calculated, and
returns the cached value. However, this only works correctly when the return
statements are identical.
Use a sensibly named local variable, rather than a dead one with a bad name.
Fixes: a60bb68219 ("x86/time: reduce rounding errors in calculations")
Signed-off-by: Andrew Cooper <andrew.cooper3@citrix.com>
Reviewed-by: Roger Pau Monné <roger.pau@citrix.com>
{
static u64 __initdata hpet_rate;
u32 hpet_id, hpet_period;
- unsigned int last;
+ unsigned int last, rem;
if ( hpet_rate )
return hpet_rate;
hpet_resume(hpet_boot_cfg);
hpet_rate = 1000000000000000ULL; /* 10^15 */
- last = do_div(hpet_rate, hpet_period);
+ rem = do_div(hpet_rate, hpet_period);
+ if ( (rem * 2) > hpet_period )
+ hpet_rate++;
- return hpet_rate + (last * 2 > hpet_period);
+ return hpet_rate;
}
void hpet_resume(u32 *boot_cfg)