As per PSCI 0.2 spec, if CPU_ON entry_point_address is 64-bit then SMC
call function ID parameter should be set to SMC64 version.
Signed-off-by: Brijesh Singh <brijeshkumar.singh@amd.com>
Reviewed-by: Julien grall <julien.grall@citrix.com>
Acked-by: Ian Campbell <ian.campbell@citrix.com>
#include <xen/smp.h>
#include <asm/psci.h>
+/*
+ * While a 64-bit OS can make calls with SMC32 calling conventions, for
+ * some calls it is necessary to use SMC64 to pass or return 64-bit values.
+ * For such calls PSCI_0_2_FN_NATIVE(x) will choose the appropriate
+ * (native-width) function ID.
+ */
+#ifdef CONFIG_ARM_64
+#define PSCI_0_2_FN_NATIVE(name) PSCI_0_2_FN64_##name
+#else
+#define PSCI_0_2_FN_NATIVE(name) PSCI_0_2_FN_##name
+#endif
+
uint32_t psci_ver;
static uint32_t psci_cpu_on_nr;
return -EOPNOTSUPP;
}
- psci_cpu_on_nr = PSCI_0_2_FN_CPU_ON;
+ psci_cpu_on_nr = PSCI_0_2_FN_NATIVE(CPU_ON);
printk(XENLOG_INFO "Using PSCI-0.2 for SMP bringup\n");