tools/libxl: don't allow IOMMU usage with PoD
authorRoger Pau Monné <roger.pau@citrix.com>
Thu, 10 Mar 2022 08:46:28 +0000 (09:46 +0100)
committerJan Beulich <jbeulich@suse.com>
Thu, 10 Mar 2022 08:46:28 +0000 (09:46 +0100)
Prevent libxl from creating guests that attempts to use PoD together
with an IOMMU, even if no devices are actually assigned.

While the hypervisor could support using PoD together with an IOMMU as
long as no devices are assigned, such usage seems doubtful. There's no
guarantee the guest has PoD no longer be active, and thus a later
assignment of a PCI device to such domain could fail.

Preventing the usage of PoD together with an IOMMU at guest creation
avoids having to add checks for active PoD entries in the device
assignment paths.

Signed-off-by: Roger Pau Monné <roger.pau@citrix.com>
Reviewed-by: Anthony PERARD <anthony.perard@citrix.com>
master commit: 07449ecfa42532495156fa342af2112e3e31dd3f
master date: 2022-02-18 09:03:08 +0100

tools/libs/light/libxl_create.c

index dcd09d32ba0b7f3e21e7faa4381c582fc063da99..2890697de888fa73944844fd9bf2ed16963cd5dd 100644 (file)
@@ -1158,17 +1158,17 @@ int libxl__domain_config_setdefault(libxl__gc *gc,
     pod_enabled = (d_config->c_info.type != LIBXL_DOMAIN_TYPE_PV) &&
         (d_config->b_info.target_memkb < d_config->b_info.max_memkb);
 
-    /* We cannot have PoD and PCI device assignment at the same time
-     * for HVM guest. It was reported that IOMMU cannot work with PoD
-     * enabled because it needs to populated entire page table for
-     * guest. To stay on the safe side, we disable PCI device
-     * assignment when PoD is enabled.
+    /* We don't support having PoD and an IOMMU at the same time for HVM
+     * guests. An active IOMMU cannot work with PoD because it needs a fully
+     * populated page-table. Prevent PoD usage if the domain has an IOMMU
+     * assigned, even if not active.
      */
     if (d_config->c_info.type != LIBXL_DOMAIN_TYPE_PV &&
-        d_config->num_pcidevs && pod_enabled) {
+        d_config->c_info.passthrough != LIBXL_PASSTHROUGH_DISABLED &&
+        pod_enabled) {
         ret = ERROR_INVAL;
         LOGD(ERROR, domid,
-             "PCI device assignment for HVM guest failed due to PoD enabled");
+             "IOMMU required for device passthrough but not supported together with PoD");
         goto error_out;
     }